Automatic Air Purger For Refrigeration Plants

Automatic Air Purger For Refrigeration Plants

Product Details:

  • Operating Temperature -20C to +60C
  • Load Capacity Suitable for systems up to 200 TR (Tons of Refrigeration)
  • Used For Removal of non-condensable gases (air, moisture) from refrigeration systems
  • Voltage 220V/380V AC
  • Surface Treatment Polished/Coated
  • Automation Grade Fully Automatic
  • Power Source Electric
  • Click to View more
X

Automatic Air Purger For Refrigeration Plants Product Specifications

  • Removal of non-condensable gases (air, moisture) from refrigeration systems
  • New
  • Suitable for systems up to 200 TR (Tons of Refrigeration)
  • Corrosion Resistant, Leakproof, Durable
  • 220V/380V AC
  • 150-300 W
  • Polished/Coated
  • Automatic
  • -20C to +60C
  • Stainless Steel / Brass
  • Fully Automatic
  • Electric
  • Up to 30 bar
  • Self-operating, Digital Display, High Sensitivity, Low Maintenance
  • Up to 100 liters per purge cycle
  • Single or Three Phase
  • Commercial & Industrial Refrigeration Plants
  • Supplied with brackets and fasteners
  • Audio/Visual Alarm for Malfunction
  • 450 x 250 x 300 mm (LxWxH)
  • Wall or Floor Mounted
  • Approximately 15-25 kg
  • 1/2" to 1" BSP/NPT
  • LED or LCD Digital Display
  • Easy Access for Maintenance
  • Mirror Polish/Satin Finish
  • Compatible with all common refrigerants (NH3, R22, R134a, R404A, etc.)
  • Suitable for Humid/Corrosive Environments
  • Automatic Solenoid Drain Valve
  • Electronic Microprocessor Based

Product Description

An electronic-controlled, completely automatic non-condensable gas (air) refrigerant purger, this Automatic Air Purger For Refrigeration Plant is used to remove air from refrigeration systems. The condensing temperature is practically kept constant by this automatic air purifier, which also ensures ideal working conditions. The amount of non-condensable gasses has significantly decreased. This Automatic Air Purger For Refrigeration Plant is made particularly to preserve the effectiveness of an ammonia refrigeration plant by eliminating any air that may be present in the refrigerant charge.


Superior Refrigerant Compatibility

This air purger seamlessly integrates with most common refrigerants like NH3, R22, R134a, and R404A, ensuring versatility for various commercial and industrial applications. The robust design accommodates different system specifications and refrigerant grades, making installation straightforward across new or existing refrigeration plants.


User-Friendly Control and Maintenance

Equipped with an advanced electronic microprocessor-based control system, the purger delivers precise operations. The audio/visual alarm system quickly alerts users to any malfunctions, while the LED or LCD display provides clear operational feedback. Easy maintenance access and included mounting accessories simplify upkeep and installation.


Reliable Performance in Tough Environments

Crafted from corrosion-resistant stainless steel or brass and featuring a mirror polish or satin finish, this device reliably operates in humid and corrosive conditions. Its automatic solenoid drain valve, leakproof construction, and fully automatic functionality make it suitable for extended use in challenging environments.

FAQ's of Automatic Air Purger For Refrigeration Plants:


Q: How does the automatic air purger improve the efficiency of refrigeration plants?

A: By actively removing non-condensable gases like air and moisture, the purger reduces pressure drop and increases heat transfer efficiency, minimizing energy consumption and protecting system components from corrosion.

Q: What is the process for installing this air purger in a refrigeration system?

A: The purger is designed for wall or floor mounting and is supplied with all necessary brackets and fasteners. It can be connected via 1/2" to 1" BSP/NPT inlet/outlet connections to compatible refrigeration systems, ensuring a secure and leakproof installation.

Q: When should an automatic air purger be operated or serviced?

A: The device runs automatically during system operation. For maintenance, its design allows easy access and cleaning, typically as recommended by the manufacturer or when prompted by the unit's audio/visual alarm indicating a malfunction.

Q: Where is the best location to install the air purger in a refrigeration plant?

A: It should be installed near the highest point of the condenser or receiver, where non-condensable gases tend to accumulate. Both wall and floor mounting options offer flexibility based on plant layout and space availability.

Q: What benefits does the digital display provide users?

A: The LED or LCD digital display offers real-time operational status, error codes, and performance metrics, enabling users to monitor conditions efficiently and address any issues promptly.

Q: Is this air purger suitable for use in corrosive or humid environments?

A: Yes, the device is engineered with corrosion-resistant materials and surface treatments, ensuring long-term durability and reliable operation even in the most demanding industrial settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Energy Saving Equipments' category



trade india member
MANIK ENGINEERS All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.